UK SRSThe UK Sustainability Reporting Standards, ESOS, SECR and TCFD, read against the published text.HUBYOU ARE HEREUK SRS GuideAn independent reference guide to UK SRS, ESG, TCFD, SECR, ESOS and the global standards.Global Reporting StandardsSustainability reporting standards worldwide: ISSB, the EU CSRD after Omnibus I, California SB 253 and SB 261, and UK SRS.UK SRS StandardsUK SRS S1 and S2 at the provision: reliefs, comply or explain, and the FCA statements.ESOS QuestESOS Phase 4 in depth: qualification, the audit, sign-off, action plans and penalties, read against the Regulations.SRS EngineeringThe data build behind a UK SRS report: metrics, owners, controls and timing.SRS ReportWhat a UK SRS report contains, how it is assembled, and how to read one.UK SRS ReportAnalysis and commentary: CDP, the DESNZ emission factors, SECR and ESOS, with every figure cited.UK SRS NewsThe cluster's news publication, and what a UK SRS report contains.UK SRS DeliveryTemplates, costs, ESOS delivery guides and readiness assessment.UK SRS FinanceFinanced emissions, PCAF and IFRS S1/S2 for banks, insurers and asset managers.SECRStreamlined Energy and Carbon Reporting: deadlines, thresholds, eligibility and guidance.Carbon CreditsCarbon credit ratings, risk analysis, valuation and market structure.Environmental RegimesThe eight UK environmental reporting regimes, their thresholds, deadlines and regulators.UK SRS ServicesThe services arm: ESOS, SECR, net zero and sustainability consultancy.

Software · building energy, cited

Building energy software: EPCs, DECs and MEES data

Building energy software holds a building’s meter, sub-meter and BMS data and the certificates built from it.

In England and Wales that data meets four legal duties at building level — MEES, DECs, EPCs and air-conditioning inspections — and feeds the company’s SECR and ESOS figures. This page sets them out and computes which apply to your building.

What it holds

What does building energy software hold?

It holds the building-level evidence that a company-level platform rarely keeps.

A carbon platform needs a building’s annual kWh; a building energy tool needs the lodgement date of its EPC, the nominated date of its DEC and the date of its last air-conditioning inspection.

The same meter history serves both, because a DEC is built from 12 months of measured use under regulation 15 of the Energy Performance of Buildings Regulations 2012.

The test of a tool is whether one reading can feed the certificate, the landlord’s evidence and the company report without being keyed three times.

  1. 1

    Meters and sub-meters

    kWh by building, floor or system; the measured basis of a DEC.

  2. 2

    BMS data

    Set points, run hours and alarms that explain why the meter moved.

  3. 3

    Certificates

    EPCs with lodgement dates, DECs, recommendation and inspection reports.

  4. 4

    Improvements

    Measures, costs and payback evidence for a let building.

  5. 5

    Company reports

    The building’s kWh in SECR and its place in the ESOS buildings purpose.

Your building

Which duties apply to this building?

Four duties attach to the building rather than the company, and each has its own trigger.

MEES follows the letting, DECs follow public occupation, air-conditioning inspections follow the plant, and Scotland runs a separate regime under SSI 2016/146.

The tool beside this takes the nation, floor area, letting, occupier and air-conditioning output, and lists the duties with their provisions.

It is a first sort: exemptions, listed buildings and part-building lets all change the answer.

Which building energy duties apply

DutyWhat it asksStatus
Minimum energy efficiency standard (MEES)A let non-domestic property that needs an EPC must not be let below band E on a valid EPC (lodged no more than 10 years before it is relied on), unless a registered exemption applies. SI 2015/962 regs 22, 27In force
EPC B from 2031 (proposal)Proposed for private rented buildings over 1,000 m², “where cost effective”, only after secondary legislation passes. Not law today. DESNZ interim response, 18 June 2026Proposed
Air-conditioning inspectionAccessible parts inspected by an energy assessor at intervals not exceeding five years; keep the latest report. SI 2012/3118 regs 18, 20In force

A first sort, not legal advice: exemptions, part-building lets and listed buildings change the answer.

Nothing is stored or sent.

EPC or DEC

Is an EPC or a DEC the better measure of a building?

They answer different questions, and a tool should keep both.

An EPC says how the building should perform; MEES relies on it, and an EPC is “valid” for MEES only if it was lodged no more than 10 years before it is relied on, under reg 22(c).

A DEC says how the building did perform, from twelve months of metered use, with the ratings of the previous two years beside it, under reg 15.

The government has decided to keep the carbon-based Environmental Impact Rating as the headline of reformed non-domestic EPCs, according to its partial response on EPC reform, which has slipped to the second half of 2027.

One
building

EPC · asset rating

Modelled performance of the fabric and services; for commercial buildings a carbon-based Environmental Impact Rating.

What MEES tests; valid for MEES if lodged no more than 10 years before it is relied on.

DEC · operational rating

Measured energy over 12 months ending no earlier than three months before the nominated date.

Shows the last two years’ ratings beside this one.

MEES

What does MEES ask of a let commercial building?

A landlord must not continue to let a non-domestic property below band E on a valid EPC, unless a registered exemption applies, under the 2015 Regulations.

The improvements a landlord must make are limited by the seven-year simple payback test in regulation 28, which compares seven years of bill savings with cost, excluding VAT, times an interest factor.

So the evidence a tool must keep is the EPC with its lodgement date, the candidate improvements with their costs and modelled savings, and any registered exemption with its expiry.

Read what changed in June 2026

DESNZ’s interim response dropped the proposed 2027 EPC C milestone and proposed EPC B from 2031 for private rented buildings over 1,000 m², “where cost effective”, only after secondary legislation passes.

Buildings below 1,000 m² are intended to stay at band E, and the payback test and exemptions remain.

The MEES-specific tooling is on MEES software, and the regime on MEES.

MEES, non-domesticExplore

MEES, non-domestic

Band E

The current minimum, England and Wales only.

Public buildings and plant

What do DECs and air-conditioning inspections require?

DEC trigger

Over 250 m²Occupied by a public authority, frequently visited by the public

DEC validity

12 monthsOver 1,000 m²; 10 years for smaller buildings

Air-con inspection

≤ 5 yearsSystems over 12 kW effective rated output

DEC for ESOS

RemovedNot a compliance route since 22 July 2026

Every occupier of a building over 250 m² that a public authority occupies and the public frequently visits must display a valid DEC at all times and hold a valid recommendation report, under regulation 14.

A DEC lasts 12 months where the floor area is over 1,000 m², and 10 years for any other building.

Separately, the relevant person for an air-conditioning system over 12 kW must have its accessible parts inspected by an energy assessor at intervals not exceeding five years and keep the latest report, under regulation 18.

A building energy tool earns its keep here as a register of dates: a DEC that lapses every year is easy to miss across a large public estate.

DECs are no longer an ESOS compliance route, after SI 2026/701, though their data can still feed an ESOS report.

Into the company report

How does building data reach SECR and ESOS?

A building’s meters are where most of a company’s SECR energy figure comes from.

SECR asks for annual energy in kWh under ¶15(3A) of Schedule 7 for quoted companies and ¶20D(3) for unquoted companies, and building electricity is converted on the DESNZ factor for the year the energy was used.

ESOS treats buildings as one of four organisational purposes, each needing its own energy intensity ratio under reg 25C.

For property portfolios, SASB’s Real Estate metric IF-RE-130a.4 asks for the share of eligible floor area with an energy rating, and GRESB’s BC2 scores energy ratings on floor-area coverage.

Portfolio emissions are covered on real estate carbon accounting software.

From building to reportExplore

From building to report

SECR kWh

Building gas and electricity in the company’s annual energy figure.

Scotland and Northern Ireland

Do the same rules apply across the UK?

Sources: SI 2015/962 · SSI 2016/146 · Energy Act 2011 s.42.
NationLet commercial buildingsSource
England and WalesMEES: band E minimum on a valid EPC; payback test; registered exemptions.SI 2015/962
ScotlandNo EPC-band letting ban. Buildings over 1,000 m² on sale or lease need an action plan, then the improvements within 42 months or annual DECs.SSI 2016/146
Northern IrelandNo private rented minimum energy efficiency instrument was found; treat as unconfirmed.Energy Act 2011 s.42 for the E&W extent

A UK estate needs a tool that knows which nation a building sits in, because the trigger, the metric and the deadline all change at the border.

An order of work

Where should a property team start?

  1. 01 / Register01

    List every building

    Nation, floor area, occupier, tenure and air-conditioning output.

    SI 2015/962

  2. 02 / Certificates02

    Load the certificates

    EPC lodgement dates, DEC nominated dates, inspection reports.

    SI 2012/3118 reg 14

  3. 03 / Meters03

    Connect the meters

    Twelve months of measured kWh by building, with gaps shown.

    reg 15

  4. 04 / Let stock04

    Test the let stock

    Band against E; improvements against the payback test; exemptions registered.

    reg 28

  5. 05 / Report05

    Roll up to the company

    Building kWh into SECR and the ESOS buildings purpose.

    Sch 7

Ratings beyond the lawExplore

Ratings beyond the law

GRESB

Energy ratings scored on floor-area coverage.

In short

What should a board take from this?

Every building carries its own duties, and the meter data behind them is the same data the company reports.

Each row is sourced in the sections above.
What is trueWhat it means for a tool
MEES is band E today, in England and Wales only.Track each let building’s band, EPC lodgement date and exemptions.
A DEC lasts 12 months over 1,000 m².Hold nominated dates and renewals for every public building.
Air conditioning over 12 kW is inspected at least every five years.Keep plant ratings and the latest report per system.
EPC B from 2031 is a proposal, not law.Model it for buildings over 1,000 m² without treating it as a deadline.
Building kWh feeds SECR and ESOS.One reading, used once, flows to every report.

Next, see how measures are proved on energy efficiency software.

This site has tested no products

Nothing on this page is a rating, ranking or recommendation of any product.

Frequently asked

Building energy software, answered

What is building energy software?

Software that holds a building’s energy data — meters, sub-meters, the building management system and its certificates — and turns it into the ratings and reports the law and investors ask for.

In the UK that means EPCs, DECs, MEES evidence and air-conditioning inspection records, plus the building’s share of SECR and ESOS figures.

What is the difference between an EPC and a DEC?

An EPC is an asset rating: it models how the building should perform.

A DEC shows the operational rating, calculated from 12 months of actual energy use ending no earlier than three months before the nominated date, alongside the ratings shown in the previous two years (SI 2012/3118 reg 15).

Which buildings need a display energy certificate?

In England and Wales, buildings over 250 m² occupied by a public authority and frequently visited by the public.

The occupier must display a valid DEC at all times and hold a valid recommendation report.

A DEC lasts 12 months over 1,000 m² and 10 years otherwise (SI 2012/3118 reg 14).

A private office has no DEC duty.

Can a DEC still be used for ESOS?

Not as a compliance route.

SI 2026/701 removed DECs and Green Deal Assessments as alternative routes from 22 July 2026.

The data behind a DEC can still feed an ESOS report.

What is the MEES minimum for commercial property?

Band E, in England and Wales.

A let non-domestic property that needs an EPC must not be let below band E on a valid EPC unless a registered exemption applies.

Non-domestic penalties can reach £50,000, or £150,000 where the breach lasts three months or more, depending on rateable value.

Is EPC B by 2030 law for commercial buildings?

No. DESNZ’s interim response of 18 June 2026 proposes EPC B from 2031 for private rented buildings over 1,000 m², where cost effective, only after secondary legislation passes.

Buildings under 1,000 m² stay at band E, and the 2027 EPC C milestone was dropped.

How often must air conditioning be inspected?

In England and Wales, the accessible parts of a system with an effective rated output over 12 kW must be inspected by an energy assessor at intervals not exceeding five years, and the latest report kept (SI 2012/3118 regs 18 and 20).

Does MEES apply in Scotland?

No. MEES is England and Wales only.

Scotland has its own non-domestic regime under SSI 2016/146: buildings over 1,000 m² need an action plan on sale or lease, followed by the improvements within 42 months or annual DECs.

What rating does a commercial EPC give?

Its headline is the carbon-based Environmental Impact Rating.

The government has decided to keep it as the single headline metric on reformed non-domestic EPCs, expressly to keep non-domestic MEES working; EPC reform has slipped to the second half of 2027.

Do investors ask for building energy ratings?

Some frameworks do.

SASB’s Real Estate metric IF-RE-130a.4 asks for the share of eligible portfolio with an energy rating, and GRESB’s 2026 Real Estate Assessment scores energy ratings on floor-area coverage.

Under UK SRS S2, an entity may refer to and consider the industry-based guidance.

Is NABERS UK required?

No. NABERS UK is a voluntary rating of measured in-use office energy on a one to six star scale, launched in the UK on 26 November 2020, with CIBSE as scheme administrator since April 2024.

Has this site tested any building energy software?

No. This page is built from the building regulations, MEES, the ESOS and SECR provisions and the frameworks named, each cited to its source. It names, ranks and prices no product.

Sources

Primary sources

Every duty on this page traces to the provision listed here.

Checked against 18 sources fromlegislation.gov.ukDepartment for Energy Security and Net ZeroMHCLG and DESNZIFRS FoundationGRESBNABERS
  1. legislation.gov.uk
    Energy Efficiency (Private Rented Property) (England and Wales) Regulations 2015, Part 3

    Band E minimum; a valid EPC is one lodged no more than 10 years before it is relied on.

  2. legislation.gov.uk
    SI 2015/962, regulation 28

    The seven-year simple payback test.

  3. legislation.gov.uk
    SI 2015/962, Part 3 Chapter 6

    Non-domestic penalties up to £50,000 or £150,000.

  4. Department for Energy Security and Net Zero
    Non-domestic MEES: interim response (18 June 2026)

    EPC B from 2031 proposed over 1,000 m²; 2027 milestone dropped.

  5. MHCLG and DESNZ
    Reforms to the Energy Performance of Buildings regime

    The carbon-based Environmental Impact Rating stays the non-domestic headline.

  6. legislation.gov.uk
    Energy Performance of Buildings (England and Wales) Regulations 2012, regulation 14

    Display energy certificates for public authority buildings over 250 m².

  7. legislation.gov.uk
    SI 2012/3118, regulation 15

    A DEC shows the measured operational rating over 12 months.

  8. legislation.gov.uk
    SI 2012/3118, regulation 18

    Air-conditioning inspections at intervals not exceeding five years.

  9. legislation.gov.uk
    Assessment of Energy Performance of Non-domestic Buildings (Scotland) Regulations 2016 (SSI 2016/146)

    Action plans for buildings over 1,000 m² on sale or lease.

  10. legislation.gov.uk
    Energy Act 2011, section 42

    MEES powers reach property in England and Wales.

  11. legislation.gov.uk
    ESOS (Amendment) Regulations 2026 (SI 2026/701)

    DECs removed as an ESOS compliance route.

  12. legislation.gov.uk
    ESOS Regulations 2014, reg 25C

    An energy intensity ratio for buildings, among the four purposes.

  13. legislation.gov.uk
    SI 2008/410, Schedule 7

    SECR: building energy in the company’s kWh and emissions.

  14. Department for Energy Security and Net Zero
    2026 GHG conversion factors methodology paper, Table 9

    UK electricity factors by year.

  15. IFRS Foundation
    SASB Standards: Real Estate, IF-RE-130a.4

    Share of portfolio floor area with an energy rating.

  16. GRESB
    2026 Real Estate Assessment, BC2 Energy ratings

    Energy ratings score on floor-area coverage.

  17. NABERS
    NABERS UK

    Measured in-use office energy ratings, one to six stars.

  18. Department for Business and Trade
    UK SRS S2 Climate-related Disclosures

    Industry-based guidance an entity may refer to and consider.